DRAFT
Point 3: When the reverse unit (Left) (K side) and processor
insertion unit (L side) are not at the same position, the
standard adjustment of reverse unit (Left) is necessary.
Point 4: When the reverse unit (Right) (H side) and processor
insertion unit (I side) are not at the same position, the
standard adjustment of reverse unit (Right) is necessary.
Mechanical adjustment (Paper advance section)
QSS-30-6
Reverse unit (Left)
Reverse unit (Right)
Processor insertion
unit
H side
I sideL side
K side
www.minilablaser.com